Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.537
Filtrar
1.
J Vis Exp ; (206)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38709031

RESUMO

Complications after lung transplantation are largely related to the host immune system responding to the graft. Such immune responses are regulated by crosstalk between donor and recipient cells. A better understanding of these processes relies on the use of preclinical animal models and is aided by an ability to study intra-graft immune cell trafficking in real-time. Intravital two-photon microscopy can be used to image tissues and organs for depths up to several hundred microns with minimal photodamage, which affords a great advantage over single-photon confocal microscopy. Selective use of transgenic mice with promoter-specific fluorescent protein expression and/or adoptive transfer of fluorescent dye-labeled cells during intravital two-photon microscopy allows for the dynamic study of single cells within their physiologic environment. Our group has developed a technique to stabilize mouse lungs, which has enabled us to image cellular dynamics in naïve lungs and orthotopically transplanted pulmonary grafts. This technique allows for detailed assessment of cellular behavior within the vasculature and in the interstitium, as well as for examination of interactions between various cell populations. This procedure can be readily learned and adapted to study immune mechanisms that regulate inflammatory and tolerogenic responses after lung transplantation. It can also be expanded to the study of other pathogenic pulmonary conditions.


Assuntos
Microscopia Intravital , Transplante de Pulmão , Animais , Camundongos , Microscopia Intravital/métodos , Transplante de Pulmão/métodos , Pulmão/imunologia , Pulmão/diagnóstico por imagem , Camundongos Transgênicos , Microscopia de Fluorescência por Excitação Multifotônica/métodos
2.
Clin Respir J ; 18(5): e13773, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38725329

RESUMO

BACKGROUND: Pulmonary alveolar microlithiasis (PAM) is a rare autosomal recessive genetic disorder with approximately 1000 known cases worldwide, in which calcium phosphate microliths deposit in the alveolar air spaces. As of writing this report, no definitive conventional therapy exists, and many PAM cases may progress to severe respiratory failure and potential death. Bilateral lung transplantation (BLx) seems to be the most optimal solution; however, this procedure is challenging along with limited reports regarding the outcome in PAM. We report a case of PAM successfully treated with BLx for the first time in Iran. METHOD: We present the case of a 42-year-old female with a longstanding history of cough, not responding to conventional antitussive medication, who was diagnosed as a case of PAM following a hospitalization due to coughing, dyspnea on exertion, and hemoptysis. Despite treatment with corticosteroid and medical treatment, no improvement was achieved and she subsequently developed respiratory and right ventricular failure, with oxygen ventilation dependence. Eventually, she was scheduled for BLx. The operation was successful and during her 2-year follow-up, no recurrence or significant postoperative complications has been reported. CONCLUSION: This case presentation and literature review confirm the effectiveness of BLx as a promising treatment for PAM-diagnosed patients, improving both life expectancy and quality of life.


Assuntos
Calcinose , Pneumopatias , Transplante de Pulmão , Humanos , Feminino , Transplante de Pulmão/métodos , Adulto , Pneumopatias/cirurgia , Pneumopatias/complicações , Calcinose/cirurgia , Calcinose/complicações , Calcinose/diagnóstico , Resultado do Tratamento , Doenças Genéticas Inatas/cirurgia , Doenças Genéticas Inatas/complicações , Doenças Genéticas Inatas/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Tosse/etiologia , Irã (Geográfico) , Qualidade de Vida
3.
Artigo em Inglês | MEDLINE | ID: mdl-38716640

RESUMO

In this video tutorial, we present a comprehensive step-by-step operative technique for a bilateral orthotopic lung transplant using a bilateral transverse thoracosternotomy in a patient with idiopathic pulmonary fibrosis lung disease. The donor lungs were exposed to extended cold static ischaemic storage at 10° C for the semi-elective operation.


Assuntos
Transplante de Pulmão , Preservação de Órgãos , Humanos , Transplante de Pulmão/métodos , Preservação de Órgãos/métodos , Fibrose Pulmonar Idiopática/cirurgia , Doadores de Tecidos , Masculino , Pessoa de Meia-Idade , Pulmão/cirurgia , Coleta de Tecidos e Órgãos/métodos
4.
Pediatr Transplant ; 28(4): e14757, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38695266

RESUMO

Pediatric lung transplantation represents a treatment option for children with advanced lung disease or pulmonary vascular disorders who are deemed an appropriate candidate. Pediatric flexible bronchoscopy is an important and evolving field that is highly relevant in the pediatric lung transplant population. It is thus important to advance our knowledge to better understand how care for children after lung transplant can be maximally optimized using pediatric bronchoscopy. Our goals are to continually improve procedural skills when performing bronchoscopy and to decrease the complication rate while acquiring adequate samples for diagnostic evaluation. Attainment of these goals is critical since allograft assessment by bronchoscopic biopsy is required for histological diagnosis of acute cellular rejection and is an important contributor to establishing chronic lung allograft dysfunction, a common complication after lung transplant. Flexible bronchoscopy with bronchoalveolar lavage and transbronchial lung biopsy plays a key role in lung transplant graft assessment. In this article, we discuss the application of bronchoscopy in pediatric lung transplant evaluation including historical approaches, our experience, and future directions not only in bronchoscopy but also in the evolving pediatric lung transplantation field. Pediatric flexible bronchoscopy has become a vital modality for diagnosing lung transplant complications in children as well as assessing therapeutic responses. Herein, we review the value of flexible bronchoscopy in the management of children after lung transplant and discuss the application of novel techniques to improve care for this complex pediatric patient population and we provide a brief update about new diagnostic techniques applied in the growing lung transplantation field.


Assuntos
Broncoscopia , Rejeição de Enxerto , Transplante de Pulmão , Humanos , Transplante de Pulmão/métodos , Broncoscopia/métodos , Criança , Rejeição de Enxerto/diagnóstico , Biópsia/métodos , Lavagem Broncoalveolar/métodos , Pulmão , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Pneumopatias/diagnóstico , Pneumopatias/cirurgia
5.
Transpl Int ; 37: 12601, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38694492

RESUMO

Controlled hypothermic storage (CHS) is a recent advance in lung transplantation (LTx) allowing preservation at temperatures higher than those achieved with traditional ice storage. The mechanisms explaining the benefits of CHS compared to conventional static ice storage (SIS) remain unclear and clinical data on safety and feasibility of lung CHS are limited. Therefore, we aimed to provide a focus review on animal experiments, molecular mechanisms, CHS devices, current clinical experience, and potential future benefits of CHS. Rabbit, canine and porcine experiments showed superior lung physiology after prolonged storage at 10°C vs. ≤4°C. In recent molecular analyses of lung CHS, better protection of mitochondrial health and higher levels of antioxidative metabolites were observed. The acquired insights into the underlying mechanisms and development of CHS devices allowed clinical application and research using CHS for lung preservation. The initial findings are promising; however, further data collection and analysis are required to draw more robust conclusions. Extended lung preservation with CHS may provide benefits to both recipients and healthcare personnel. Reduced time pressure between procurement and transplantation introduces flexibility allowing better decision-making and overnight bridging by delaying transplantation to daytime without compromising outcome.


Assuntos
Transplante de Pulmão , Pulmão , Preservação de Órgãos , Animais , Preservação de Órgãos/métodos , Transplante de Pulmão/métodos , Humanos , Suínos , Pulmão/fisiologia , Cães , Coelhos , Criopreservação/métodos
6.
Front Immunol ; 15: 1365964, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38585271

RESUMO

Ex-vivo lung perfusion (EVLP) has extended the number of transplantable lungs by reconditioning marginal organs. However, EVLP is performed at 37°C without homeostatic regulation leading to metabolic wastes' accumulation in the perfusate and, as a corrective measure, the costly perfusate is repeatedly replaced during the standard of care procedure. As an interesting alternative, a hemodialyzer could be placed on the EVLP circuit, which was previously shown to rebalance the perfusate composition and to maintain lung function and viability without appearing to impact the global gene expression in the lung. Here, we assessed the biological effects of a hemodialyzer during EVLP by performing biochemical and refined functional genomic analyses over a 12h procedure in a pig model. We found that dialysis stabilized electrolytic and metabolic parameters of the perfusate but enhanced the gene expression and protein accumulation of several inflammatory cytokines and promoted a genomic profile predicting higher endothelial activation already at 6h and higher immune cytokine signaling at 12h. Therefore, epuration of EVLP with a dialyzer, while correcting features of the perfusate composition and maintaining the respiratory function, promotes inflammatory responses in the tissue. This finding suggests that modifying the metabolite composition of the perfusate by dialysis during EVLP can have detrimental effects on the tissue response and that this strategy should not be transferred as such to the clinic.


Assuntos
Transplante de Pulmão , Suínos , Animais , Perfusão/métodos , Transplante de Pulmão/métodos , Preservação de Órgãos/métodos , Diálise Renal , Pulmão/fisiologia
7.
Ann Transplant ; 29: e943652, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38590090

RESUMO

BACKGROUND Anemia is common in post-transplant patients. Blood product transfusion is associated with mortality and rejection in solid organ transplants. In lung transplant recipients, transfusion predisposes to primary graft dysfunction (PGD). The adverse effects and associated mortality of perioperative transfusions in lung transplant recipients have not been evaluated. This study examined the effects of perioperative blood transfusions in lung transplant recipients. MATERIAL AND METHODS We conducted a retrospective study of the effects of blood product transfusions in patients who received single- or double-lung transplantation at Houston Methodist Hospital between August 2017 and September 2019. Univariable and multiple logistic regression modeling were used to determine the characteristics associated with single events as well as a composite outcome within 30 days (including mortality, acute myocardial infarction, acute stroke, lower respiratory tract infection, urinary tract infection, surgical site infections, or PGD). RESULTS A total of 232 patients received lung transplants between December 2015 and September 2019 at our center. Univariable analysis revealed an increased risk of PGD (P<0.001), more mechanical ventilation days (P<0.001), more ICU days post-transplant (P<0.001), and greater need for ECMO support (P=0.001) in patients who received blood product transfusions. In univariate analysis, the composite outcome was also more common (P=0.01) in patients who received any transfusion perioperatively. A total of 7 patients died within 30 days from transplant, and they were all in the transfused group. CONCLUSIONS Among lung transplant recipients, PGD, ICU days, need for mechanical ventilation and ECMO support, and total composite events were significantly greater in patients who received blood transfusion perioperatively.


Assuntos
Transplante de Pulmão , Pulmão , Humanos , Estudos de Coortes , Estudos Retrospectivos , Transfusão de Sangue , Transplante de Pulmão/efeitos adversos , Transplante de Pulmão/métodos
8.
Sci Rep ; 14(1): 7040, 2024 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575597

RESUMO

Whole lung engineering and the transplantation of its products is an ambitious goal and ultimately a viable solution for alleviating the donor-shortage crisis for lung transplants. There are several limitations currently impeding progress in the field with a major obstacle being efficient revascularization of decellularized scaffolds, which requires an extremely large number of cells when using larger pre-clinical animal models. Here, we developed a simple but effective experimental pulmonary bioengineering platform by utilizing the lung as a scaffold. Revascularization of pulmonary vasculature using human umbilical cord vein endothelial cells was feasible using a novel in-house developed perfusion-based bioreactor. The endothelial lumens formed in the peripheral alveolar area were confirmed using a transmission electron microscope. The quality of engineered lung vasculature was evaluated using box-counting analysis of histological images. The engineered mouse lungs were successfully transplanted into the orthotopic thoracic cavity. The engineered vasculature in the lung scaffold showed blood perfusion after transplantation without significant hemorrhage. The mouse-based lung bioengineering system can be utilized as an efficient ex-vivo screening platform for lung tissue engineering.


Assuntos
Células Endoteliais , Transplante de Pulmão , Animais , Humanos , Alicerces Teciduais , Pulmão/irrigação sanguínea , Engenharia Tecidual/métodos , Transplante de Pulmão/métodos , Perfusão , Reatores Biológicos , Matriz Extracelular
9.
Transpl Int ; 37: 12752, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38585623

RESUMO

Background: Extracorporeal membrane oxygenation (ECMO) is frequently used during lung transplantation. Unfractionated heparin (UFH) is mainly used as part of ECMO support for anticoagulation. One of the most common perioperative complications is bleeding, which high-dose UFH can aggravate. Methods: We retrospectively analyzed (n = 141) patients who underwent lung transplantation between 2020 and 2022. All subjects (n = 109) underwent central cannulated VA ECMO with successful intraoperative ECMO weaning. Patients on ECMO bridge, postoperative ECMO, heart-lung transplants and transplants without ECMO were excluded. The dose of UFH for the entire surgical procedure, blood loss and consumption of blood derivatives intraoperatively and 48 h after ICU admission were recorded. Surgical revision for postoperative bleeding were analyzed. Thrombotic complications, mortality and long-term survival were evaluated. Results: Lower doses of UFH administered for intraoperative ECMO anticoagulation contribute to a reduction in intraoperative blood derivates consumption and blood loss with no thrombotic complications related to the patient or the ECMO circuit. Lower doses of UFH may lead to a decreased incidence of surgical revision for hemothorax. Conclusion: Lower doses of UFH as part of intraoperative ECMO anticoagulation might reduce the incidence of complications and lead to better postoperative outcomes.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Pulmão , Trombose , Humanos , Heparina/uso terapêutico , Estudos Retrospectivos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Anticoagulantes/uso terapêutico , Transplante de Pulmão/métodos , Trombose/etiologia , Hemorragia Pós-Operatória
10.
Front Immunol ; 15: 1358153, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38510260

RESUMO

Primary graft dysfunction (PGD) is a common complication after lung transplantation. A plethora of contributing factors are known and assessment of donor lung function prior to organ retrieval is mandatory for determination of lung quality. Specialized centers increasingly perform ex vivo lung perfusion (EVLP) to further assess lung functionality and improve and extend lung preservation with the aim to increase lung utilization. EVLP can be performed following different protocols. The impact of the individual EVLP parameters on PGD development, organ function and postoperative outcome remains to be fully investigated. The variables relate to the engineering and function of the respective perfusion devices, such as the type of pump used, functional, like ventilation modes or physiological (e.g. perfusion solutions). This review reflects on the individual technical and fluid components relevant to EVLP and their respective impact on inflammatory response and outcome. We discuss key components of EVLP protocols and options for further improvement of EVLP in regard to PGD. This review offers an overview of available options for centers establishing an EVLP program and for researchers looking for ways to adapt existing protocols.


Assuntos
Lesão Pulmonar , Transplante de Pulmão , Humanos , Pulmão , Perfusão/métodos , Transplante de Pulmão/efeitos adversos , Transplante de Pulmão/métodos , Doadores de Tecidos
11.
Transpl Int ; 37: 12573, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38481465

RESUMO

With the ongoing shortage of donor lungs, ex vivo lung perfusion (EVLP) offers the opportunity for objective assessment and potential therapeutic repair of marginal organs. There is a need for robust research on EVLP interventions to increase the number of transplantable organs. The use of human lungs, which have been declined for transplant, for these studies is preferable to animal organs and is indeed essential if clinical translation is to be achieved. However, experimental human EVLP is time-consuming and expensive, limiting the rate at which promising interventions can be assessed. A split-lung EVLP model, which allows stable perfusion and ventilation of two single lungs from the same donor, offers advantages scientifically, financially and in time to yield results. Identical parallel circuits allow one to receive an intervention and the other to act as a control, removing inter-donor variation between study groups. Continuous hemodynamic and airway parameters are recorded and blood gas, perfusate, and tissue sampling are facilitated. Pulmonary edema is assessed directly using ultrasound, and indirectly using the lung tissue wet:dry ratio. Evans blue dye leaks into the tissue and can quantify vascular endothelial permeability. The split-lung ex vivo perfusion model offers a cost-effective, reliable platform for testing therapeutic interventions with relatively small sample sizes.


Assuntos
Transplante de Pulmão , Animais , Humanos , Transplante de Pulmão/métodos , Análise Custo-Benefício , Pulmão , Circulação Extracorpórea/métodos , Perfusão/métodos , Doadores de Tecidos
13.
Transpl Int ; 37: 12310, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38317690

RESUMO

Since the early days of clinical lung transplantation the preservation of donor organs has become a fairly standardized procedure and most centers do follow similar processes. This includes the use of low-potassium high dextran flush solutions and static cold storage (SCS) in a cooler filled with ice. Depending on the length of SCS, organs usually arrive at the recipient hospital at a temperature of 0°C-4°C. The question of the optimal storage temperature for donor lung preservation has been revisited as data from large animal experiments demonstrated that organs stored at 10°C experience less mitochondrial damage. Thus, prolonged cold ischemic times can be better tolerated at 10°C-even in pre-damaged organs. The clinical applicability of these findings was demonstrated in an international multi-center observational study including three high-volume lung transplant centers. Total clinical preservation times of up to 24 hrs have been successfully achieved in organs stored at 10°C without hampering primary organ function and short-term outcomes. Currently, a randomized-controlled trial (RCT) is recruiting patients with the aim to compare standard SCS on ice with prolonged SCS protocol at 10°C. If, as anticipated, this RCT confirms data from previous studies, lung transplantation could indeed become a semi-elective procedure.


Assuntos
Transplante de Pulmão , Preservação de Órgãos , Animais , Humanos , Temperatura Baixa , Gelo , Pulmão , Transplante de Pulmão/métodos , Estudos Observacionais como Assunto , Preservação de Órgãos/métodos , Perfusão/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Temperatura , Estudos Multicêntricos como Assunto
14.
J Vis Exp ; (203)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38345240

RESUMO

Over the past decade, our laboratory has made significant progress in developing and refining vascularized mouse lung transplantation models using an efficient and highly reliable "cuff technique" of transplantation. This article describes a sophisticated and comprehensive method for orthotopic lung transplantation in a vascularized orthotopic lung model, representing the most physiologic and clinically relevant model of mouse lung transplantation to date. The transplantation process consists of two distinct stages: donor harvest and subsequent implantation into the recipient. The method has been successfully mastered, and with several months of sufficient training, a skilled practitioner can perform the procedure in approximately 90 min from skin-to-skin. Surprisingly, once individuals overcome the initial learning curve, the survival rate during the perioperative period approaches nearly 100%. The mouse model allows for the use of multiple commercially available transgenic and mutant strains of mice, enabling the study of tolerance and rejection. Additionally, the unique features of this model make it a valuable tool for investigating tumor biology and immunology.


Assuntos
Transplante de Pulmão , Camundongos , Animais , Transplante de Pulmão/métodos , Pulmão/cirurgia , Modelos Animais de Doenças , Animais Geneticamente Modificados
15.
J Heart Lung Transplant ; 43(5): 838-848, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38310996

RESUMO

Engineering donor organs to better tolerate the harmful non-immunological and immunological responses inherently related to solid organ transplantation would improve transplant outcomes. Our enhanced knowledge of ischemia-reperfusion injury, alloimmune responses and pathological fibroproliferation after organ transplantation, and the advanced toolkit available for gene therapies, have brought this goal closer to clinical reality. Ex vivo organ perfusion has evolved rapidly especially in the field of lung transplantation, where clinicians routinely use ex vivo lung perfusion (EVLP) to confirm the quality of marginal donor lungs before transplantation, enabling safe transplantation of organs originally considered unusable. EVLP would also be an attractive platform to deliver gene therapies, as treatments could be administered to an isolated organ before transplantation, thereby providing a window for sophisticated organ engineering while minimizing off-target effects to the recipient. Here, we review the status of lung transplant first-generation gene therapies that focus on inducing transgene expression in the target cells. We also highlight recent advances in next-generation gene therapies, that enable gene editing and epigenetic engineering, that could be used to permanently change the donor organ genome and to induce widespread transcriptional gene expression modulation in the donor lung. In a future vision, dedicated organ repair and engineering centers will use gene editing and epigenetic engineering, to not only increase the donor organ pool, but to create superior organs that will function better and longer in the recipient.


Assuntos
Terapia Genética , Transplante de Pulmão , Perfusão , Transplante de Pulmão/métodos , Humanos , Terapia Genética/métodos , Perfusão/métodos , Pulmão , Preservação de Órgãos/métodos , Animais
17.
J Surg Res ; 296: 47-55, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38219506

RESUMO

INTRODUCTION: Primary graft dysfunction (PGD) is a known risk factor for early mortality following lung transplant (LT). However, the outcomes of patients who achieve long-term survival following index hospitalization are unknown. We aimed to determine the long-term association of PGD grade 3 (PGD3) in patients without in-hospital mortality. METHODS: LT recipients were identified from the United Network for Organ Sharing Database. Patients were stratified based on the grade of PGD at 72 h (No PGD, Grade 1/2 or Grade 3). Groups were assessed with comparative statistics. Long-term survival was evaluated using Kaplan-Meier methods and a multivariable shared frailty model including recipient, donor, and transplant characteristics. RESULTS: The PGD3 group had significantly increased length of stay, dialysis, and treated rejection post-transplant (P < 0.001). Unadjusted survival analysis revealed a significant difference in long-term survival (P < 0.001) between groups; however, following adjustment, PGD3 was not independently associated with long-term survival (hazard ratio: 0.972; 95% confidence interval: 0.862-1.096). Increased mortality was significantly associated with increased recipient age and treated rejection. Decreased mortality was significantly associated with no donor diabetes, bilateral LT as compared to single LT, transplant in 2015-2016 and 2017-2018, and no post-transplant dialysis. CONCLUSIONS: While PGD3 remains a challenge post LT, PGD3 at 72 h is not independently associated with decreased long-term survival, while complications such as dialysis and rejection are, in patients who survive index hospitalization. Transplant providers should be aggressive in preventing further complications in recipients with severe PGD to minimize the negative association on long-term survival.


Assuntos
Transplante de Pulmão , Disfunção Primária do Enxerto , Humanos , Disfunção Primária do Enxerto/epidemiologia , Disfunção Primária do Enxerto/etiologia , Transplante de Pulmão/efeitos adversos , Transplante de Pulmão/métodos , Fatores de Risco , Análise de Sobrevida , Doadores de Tecidos , Estudos Retrospectivos , Sobrevivência de Enxerto
18.
Chirurgie (Heidelb) ; 95(2): 108-114, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-38191810

RESUMO

Lung transplantation is currently the gold standard treatment for end-stage lung diseases. Advances in the preservation of donor lungs, the surgical technique and immunosuppressive therapy have led to lung transplantation now being a routine procedure. Nevertheless, the shortage of donor organs, the acute and particularly chronic lung allograft dysfunction (CLAD) still represent major challenges even in experienced centers. Research in this area is still necessary to improve the long-term survival of lung recipients.


Assuntos
Transplante de Pulmão , Humanos , Terapia de Imunossupressão , Pulmão/patologia , Pulmão/cirurgia , Transplante de Pulmão/métodos , Transplante de Pulmão/tendências , Tórax , Doadores de Tecidos
19.
ASAIO J ; 70(5): 442-450, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38266069

RESUMO

Normothermic ex vivo lung perfusion (EVLP) can resuscitate marginal lung allografts to increase organs available for transplantation. During normothermic perfusion, cellular metabolism is more active compared with subnormothermic perfusion, creating a need for an oxygen (O 2 ) carrier in the perfusate. As an O 2 carrier, red blood cells (RBCs) are a scarce resource and are susceptible to hemolysis in perfusion circuits, thus releasing cell-free hemoglobin (Hb), which can extravasate into the tissue space, thus promoting scavenging of nitric oxide (NO) and oxidative tissue damage. Fortunately, polymerized human Hb (PolyhHb) represents a synthetic O 2 carrier with a larger molecular diameter compared with Hb, preventing extravasation, and limiting adverse reactions. In this study, a next-generation PolyhHb-based perfusate was compared to both RBC and asanguinous perfusates in a rat EVLP model. During EVLP, the pulmonary arterial pressure and pulmonary vascular resistance were both significantly higher in lungs perfused with RBCs, which is consistent with RBC hemolysis. Lungs perfused with PolyhHb demonstrated greater oxygenation than those perfused with RBCs. Post-EVLP analysis revealed that the PolyhHb perfusate elicited less cellular damage, extravasation, iron tissue deposition, and edema than either RBCs or colloid control. These results show promise for a next-generation PolyhHb to maintain lung function throughout EVLP.


Assuntos
Substitutos Sanguíneos , Hemoglobinas , Transplante de Pulmão , Perfusão , Ratos Sprague-Dawley , Hemoglobinas/administração & dosagem , Animais , Transplante de Pulmão/métodos , Transplante de Pulmão/efeitos adversos , Ratos , Perfusão/métodos , Humanos , Substitutos Sanguíneos/farmacologia , Masculino , Pulmão , Oxigênio/metabolismo , Aloenxertos , Hemólise/efeitos dos fármacos , Eritrócitos
20.
Ann Thorac Surg ; 117(2): 413-421, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37031770

RESUMO

BACKGROUND: There is no consensus on the optimal allograft sizing strategy for lung transplantation in restrictive lung disease. Current methods that are based on predicted total lung capacity (pTLC) ratios do not account for the diminutive recipient chest size. The study investigators hypothesized that a new sizing ratio incorporating preoperative recipient computed tomographic lung volumes (CTVol) would be associated with postoperative outcomes. METHODS: A retrospective single-institution study was conducted of adults undergoing primary bilateral lung transplantation between January 2016 and July 2020 for restrictive lung disease. CTVol was computed for recipients by using advanced segmentation software. Two sizing ratios were calculated: pTLC ratio (pTLCdonor/pTLCrecipient) and a new volumetric ratio (pTLCdonor/CTVolrecipient). Patients were divided into reference, oversized, and undersized groups on the basis of ratio quintiles, and multivariable models were used to assess the effect of the ratios on primary graft dysfunction and survival. RESULTS: CTVol was successfully acquired in 218 of 220 (99.1%) patients. In adjusted analysis, undersizing on the basis of the volumetric ratio was independently associated with decreased primary graft dysfunction grade 2 or 3 within 72 hours (odds ratio, 0.42; 95% CI, 0.20-0.87; P =.02). The pTLC ratio was not significantly associated with primary graft dysfunction. Oversizing on the basis of the volumetric ratio was independently associated with an increased risk of death (hazard ratio, 2.27; 95% CI, 1.04-4.99; P =.04], whereas the pTLC ratio did not have a significant survival association. CONCLUSIONS: Using computed tomography-acquired lung volumes for donor-recipient size matching in lung transplantation is feasible with advanced segmentation software. This method may be more predictive of outcome compared with current sizing methods, which use gender and height only.


Assuntos
Pneumopatias , Transplante de Pulmão , Disfunção Primária do Enxerto , Adulto , Humanos , Pulmão/cirurgia , Estudos Retrospectivos , Disfunção Primária do Enxerto/etiologia , Tamanho do Órgão , Transplante de Pulmão/métodos , Pneumopatias/cirurgia , Doadores de Tecidos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA